Forsaire™ Counterflow Furnaces

Top-Vent Counterflow

Models require less than one square foot of floor space.  They may be recessed into the stud space or surface mounted and vented vertically through the ceiling and roof.

Direct-Vent Counterflow

The forced-air circulation comfort heating system uses only outside air for combustion, as the burners are completely sealed within the combustion chamber.  Combustion products are discharged outdoors through the wall vent.  This eliminates the expense of a vent.  All vent caps include a built-in “Bird Guard.”  All vent material is included. Ideal for garages.

Design Features
  • Freestanding or recessed, Forsaire™ furnaces are ideal for homes, apartments, offices, schools, cabins and many other applications
  • Counterflow blower system circulates ceiling-to-floor warm air
  • “Matchless” pilot igniter
  • Multi-room heating with optional outlet accessories to heat up to three rooms
  • Equipped with a four-foot service cord
  • Natural or propane models (conversion kits available)
  • Automatic temperature and safety controls
  • Resettable vent-limit safety switch (top-vent models)
  • Thermostat Sold Separately - Part #8967

Register your Williams furnace

Learn how to register here

“Matchless Pilot Igniter”
All models include a “matchless” pilot igniter. Assures convenient pilot lighting without matches.

Thermostat Sold Separately - Part number: 8967

Contemporary Finish
Soft-white, powder-coated, high-heat resistant finish to complement any décor.

Dimensions and Clearances

Top-Vent

  • 4" to an intersecting wall
  • 4" from the top of the furnace to the ceiling or overhang
  • 2" from the top of the furnace to the ceiling or overhang on 60085 Series
  • 0" to finished floor

Direct Vent

  • 4" to an intersecting wall
  • 4" from the top of the furnace to the ceiling or overhang
  • 0" to finished floor
  • 59" from the finished floor to the center line of the vent cap for Model Series 40073 and 40077
  • 68 1/2" from the finished floor to the center line of the vent cap for Model Series 55073 and 62577

4318       Vent Shield Deflector 

6701       Side Outlet Register with 10" Boot for Top- and Direct-Vent Furnaces

6702       Side Casing Grille for all Top- and Direct-Vent Furnaces

6703       Two-Way Diffusing Grille

6704       One-Way Diffusing Grille  

6802       Rear Outlet Register with 1" Boot and Damper for Top-Vent Furnaces

7A311    High Altitude Conversion Kit with all Required Orifices for 3508232

7A312    High Altitude Conversion Kit with all Required Orifices for 3508231

7A313    High Altitude Conversion Kit with all Required Orifices for 3508631

7A314    High Altitude Conversion Kit with all Required Orifices for 3508631

7A315    High Altitude Conversion Kit with all Required Orifices for 5008632

7A316    High Altitude Conversion Kit with all Required Orifices for 5008631

7A317    High Altitude Conversion Kit with all Required Orifices for 5008232

7A318    High Altitude Conversion Kit with all Required Orifices for 5008231

7A319    High Altitude Conversion Kit with all Required Orifices for 6008832

7A320    High Altitude Conversion Kit with all Required Orifices for 6008831

7A321    High Altitude Conversion Kit with all Required Orifices for 6508632

7A322    High Altitude Conversion Kit with all Required Orifices for 6508631

7A323    High Altitude Conversion Kit with all Required Orifices for 4007332 and 4007732

7A324    High Altitude Conversion Kit with all Required Orifices for 4007331 and 4007731

7A325    High Altitude Conversion Kit with all Required Orifices for 5507332

7A326    High Altitude Conversion Kit with all Required Orifices for 5507331

7A327    High Altitude Conversion Kit with all Required Orifices for 6007732

7A328    High Altitude Conversion Kit with all Required Orifices for 6007731

7689       Gas Conversion Kit - Natural Gas to Propane Gas - 60077 Series

7696       Gas Conversion Kit - Propane Gas to Natural Gas - 60077 Series

7716       Gas Conversion Kit - Natural Gas to Propane Gas - 35082 Series

7717       Gas Conversion Kit - Propane Gas to Natural Gas - 35082 Series

7718       Gas Conversion Kit - Natural Gas to Propane Gas - 35086 Series

7719       Gas Conversion Kit - Propane Gas to Natural Gas - 35086 Series

7720       Gas Conversion Kit - Natural Gas to Propane Gas - 50086 Series

7721       Gas Conversion Kit - Propane Gas to Natural Gas - 50086 Series

7722       Gas Conversion Kit - Natural Gas to Propane Gas - 55082 Series

7723       Gas Conversion Kit - Propane Gas to Natural Gas - 55082 Series

7724       Gas Conversion Kit - Natural Gas to Propane Gas - 60088 Series

7725       Gas Conversion Kit - Propane Gas to Natural Gas - 60088 Series

7726       Gas Conversion Kit - Natural Gas to Propane Gas - 65086 Series

7727       Gas Conversion Kit - Propane Gas to Natural Gas - 65086 Series

7728       Gas Conversion Kit - Natural Gas to Propane Gas - 40073 and 40077 Series

7729       Gas Conversion Kit - Propane Gas to Natural Gas - 40073 and 40077 Series

7730       Gas Conversion Kit - Natural Gas to Propane Gas - 55073 Series

7731       Gas Conversion Kit - Propane Gas to Natural Gas - 55073 Series

7732       Gas Conversion Kit - Natural Gas to Propane Gas - 60077 Series

7733       Gas Conversion Kit - Propane Gas to Natural Gas - 60077 Series

9802       Vent Cap and Tubes for Direct-Vent Furnaces, 9" Length for 40077, 40073, 55073 Series

9806       Vent Tubes for Direct-Vent Furnaces, 12" Length

9807       Thin-Wall Collar Kit for Direct-Vent Furnaces

9808       Vent Cap Guard

9809       Vent Cap and Tubes for Direct-Vent Furnaces, 9" Length for 60077 Series

9812       Vent Enclosure, 12" Length for Top-Vent Furnaces

9824       Vent Enclosure, 24" Length for Top-Vent Furnaces

9836       Vent Enclosure, 36" Length for Top-Vent Furnaces

9902       Vent Adapter (Freestanding Installations) without a Blower Installed

9910       Vent Adapter (Freestanding Installations) with a Blower Installed

9928       Universal Adapter Kit - 4" Round

9929       Oval Vent Starter Kit (includes hold-down plate) - USA

9930       Oval Vent Starter Kit (includes hold-down plate) - Canada

9940       Hard-Wire Converter

P322016 Thermostat (image)

  • Any warranty considerations are contingent on installation by a qualified installer (contractor). Self-installation is prohibited and will invalidate your warranty.
  • Read owner’s manual before using/installing.
  • Photographs are representative only.
  • Check local codes and ordinances for permitted uses.
  • Consult installation manual for clearances prior to installation.
  • We reserve the right to amend product specifications without notice.
  • Installation and servicing recommended by a qualified service person.
  • Venting must comply with the installation manual.
  • Massachusetts approval G1-0713-515.
  • Please read the warranty for any limitations or disclaimers.
  • Combustion chamber carries a ten-year limited warranty. All other parts carry a one-year limited warranty.

Exploded Model View

Not optimal for viewing on Internet Explorer browser. Please use others such as Chrome, Edge, Firefox, etc.

Similar Products

Monterey Top Vent

More Info Furnace
More...

Affordable and energy-efficient, the Monterey Home Furnace is a traditional home comfort system that delivers both quality performance and low operating costs. Recessed or surface-mounted installation. 25,000, 35,000 and 50,000 Btu/hr. sizes.

Monterey Plus Top Vent

More Info Furnace
More...

Affordable and energy-efficient, the Monterey Plus+ Home Furnaces are a traditional home comfort system that delivers both quality performance and low operating costs. Recessed or surface-mounted installation. 25,000, 35,000 and 50,000 Btu/hr. sizes.

Direct Vent

More Info Furnace
More...

Compact, space-saving furnaces featuring simple, low-cost installation. Attractive and economical, Direct-Vent furnaces are a popular choice for heating the home. 14,000, 22,000 and 30,000 Btu/hr. sizes.

High Efficiency Direct Vent

More Info Furnace
More...

A low profile furnace that may be installed nearly anywhere. Great for homes, apartments, offices, garages and room additions. Natural and Propane models. 7,400 & 17,700 Btu/hr.

Forsaire Counterflow

More Info Furnace
More...

Top-Vent Counterflow
Models require less than one square foot of floor space. They may be recessed into the stud space or surface mounted and vented vertically through the ceiling and roof.

Direct-Vent Counterflow
The forced-air circulation comfort heating system uses only outside air for combustion, as the burners are completely sealed within the combustion chamber. Combustion products are discharged outdoors through the wall vent. This eliminates the expense of a vent. All vent caps include a built-in “Bird Guard.” All vent material is included. Ideal for garages.

Electric Forsaire Counterflow

More Info Furnace
More...

Top-Vent Counterflow

Freestanding or recessed, Forsaire Electric Furnaces are ideal for homes, apartments, offices, schools cabins and many other applications.

Direct-Vent Counterflow
The forced-air circulation comfort heating system uses only outside air for combustion, as the burners are completely sealed within the combustion chamber. Combustion products are discharged outdoors through the wall vent. This eliminates the expense of a vent. All vent caps include a built-in “Bird Guard.” All vent material is included. Ideal for garages.

Vented Room Heaters

More Info Furnace
More...

Williams Vented Room Console Heaters deliver maximum efficiency, low fuel consumption and quiet operation. Enjoy instant warmth with this universal heating system. Enclosed front and glass front fireplace-look models available. 20,000, 35,000, 50,000 and 65,000 Btu/hr. sizes.

Floor Furnace

More Info Furnace
More...

A quiet, space-saving solution for large area heating requirements, the Williams Floor Furnace circulates warm air without the aid of a blower. Combustion chamber lifts out for easy servicing. 45,000 or 60,000 Btu/hr.

WARNING: This product can expose you to chemicals including epichlorohydrin which is known to the State of California to cause cancer and birth defects and/or other reproductive harm. For more information go to www.p65warnings.ca.gov